Сегодня 17 ноября 2024
Медикус в соцсетях
 
Задать вопрос

ЗАДАТЬ ВОПРОС РЕДАКТОРУ РАЗДЕЛА (ответ в течение нескольких дней)

Представьтесь:
E-mail:
Не публикуется
служит для обратной связи
Антиспам - не удалять!
Ваш вопрос:
Получать ответы и новости раздела
20 мая 2002 00:00   |   Marc P. Buijsrogge, MDa, Cees W.J. Verlaana, Mattie H.P. van Rijen, BSa, Paul F. Gründeman, MD, PhD*a, Cornelius Borst, MD, PhDa

Coronary end-to-side sleeve anastomosis using adhesive in off-pump bypass grafting in the pig

Background. In the exploration of facilitated coronary anastomosis strategies, we assessed a new octyl-cyanoacrylate adhesive in combination with a modified end-to-side sleeve anastomosis in off-pump bypass grafting in the pig.
Methods. Sleeve-adhesive anastomoses (n = 20) were evaluated intraoperatively, at 3 days (n = 4), and at 5 weeks (n = 16) in an off-pump, low (<=15 mL/min; n = 10) and high flow (approximately 60 mL/min; n = 10) porcine bypass model. All anastomoses were examined by flow measurement, angiography, and histology.
Results. Anastomosis construction took 8.5 minutes (6.7 to 10.2 minutes; median [15th to 85th percentile]). At 5 weeks, all anastomoses were fully patent (FitzGibbon grade A). The adhesive did not cause impaired vessel wall healing, but was surrounded by a focal acute and limited chronic (foreign body giant cells occasionally seen) inflammatory reaction at the adventitial application site.
Conclusions. Octyl-cyanoacrylate tissue adhesive combined with end-to-side internal mammary to coronary artery sleeve anastomosis construction proved to be feasible, even in low bypass graft flow conditions (15 mL/min; prothrombotic milieu) in the pig and deserves interest in exploration of facilitated anastomosis strategies in coronary artery bypass grafting.

Поделиться:




Комментарии
Смотри также
20 мая 2002  |  00:05
Intraoperative evaluation of coronary anastomosis by transit-time ultrasonic flow measurement
Background. Intraoperative assessment of the anastomosis is important during coronary bypass on a beating heart. The purpose of this study is to predict the quality of anastomosis using transit-time
20 мая 2002  |  00:05
Repetitive atrial flutter as a complication of the left-sided simple maze procedure
Background. Of 41 patients who had undergone a left-sided simple maze procedure, 4 (9.8%) developed repetitive tachycardia due to atrial flutter, and required radiofrequency catheter ablation.
20 мая 2002  |  00:05
Hemodynamic stability during 17 years of the Carpentier-Edwards aortic pericardial bioprosthesis
Background. Long-term stability of the hemodynamic performance of commercially available Carpentier-Edwards stented bovine pericardial aortic bioprostheses (Perimount RSR) is unknown. To anticipate
20 мая 2002  |  00:05
Long-term results of aortic valve regurgitation after repair of ruptured sinus of valsalva aneurysm
Background. We reviewed our 35-year-experience to investigate the determinants of long-term results of aortic valve regurgitation (AR) after surgical repair of ruptured sinus of Valsalva aneurysms
20 мая 2002  |  00:05
Long-term survival and quality of life in cardiac surgical patients with prolonged intensive care unit length of stay
Background. Patients with prolonged intensive care unit (ICU) stays after cardiac operations are labor intensive and expensive. We sought to determine whether exhaustive ICU efforts result in