Сегодня 17 ноября 2024
Медикус в соцсетях
 
Задать вопрос

ЗАДАТЬ ВОПРОС РЕДАКТОРУ РАЗДЕЛА (ответ в течение нескольких дней)

Представьтесь:
E-mail:
Не публикуется
служит для обратной связи
Антиспам - не удалять!
Ваш вопрос:
Получать ответы и новости раздела
17 декабря 2001 00:00   |   Aldo D. Milano, MDa, Claudio Blanzola, MDa, Gianclaudio Mecozzi,

Hemodynamic performance of stented and stentless aortic bioprostheses

 
Aldo D. Milano, MDa, Claudio Blanzola, MDa, Gianclaudio Mecozzi, MDa, Alessandro D’Alfonso, MDa, Marco De Carlo, MDb, Carmela Nardi, MDb, Uberto Bortolotti, MDa a Division of Cardiac Surgery, Cardiac and Thoracic Department, University of Pisa Medical School, Pisa, Italy
b Division of Cardiology, Cardiac and Thoracic Department, University of Pisa Medical School, Pisa, Italy
Accepted for publication March 27, 2001.
Address reprint requests to Dr Bortolotti, U.O. Cardiochirurgia, Ospedale Cisanello, Via Paradisa 2, 56124 Pisa, Italy
e-mail: u.bortolotti@cardchir.med.unipi.it
Background. This study compares the hemodynamic performance of stented and stentless bioprostheses used for aortic valve replacement in patients with aortic stenosis and small aortic root.
Methods. Between 1995 and 1998, 37 patients with a 21−mm aortic annulus (group 1) underwent aortic valve replacement with either a 21−mm Edwards Perimount or a 23−mm St. Jude Toronto bioprosthesis whereas 47 patients with a 23−mm aortic annulus (group 2) received either a 23−mm Medtronic Mosaic or a 25−mm Edwards Prima bioprosthesis. In each group mean and peak gradients, effective orifice area index, and left ventricular mass index were compared during follow-up.
Results. Group 1 patients showed a significant reduction of mean (p < 0.001) and peak gradients (p = 0.001) during follow-up, more evident for St. Jude Toronto versus Edwards Perimount (p = 0.02 and p = 0.05, respectively). Group 2 patients showed a significant reduction of mean and peak gradients (p < 0.001), more evident for Edwards Prima versus Medtronic Mosaic (p < 0.001 and p = 0.07, respectively). Effective orifice area index significantly increased only in group 1 (p = 0.005). Left ventricular mass index significantly decreased in all patients regardless of the type of valve (p < 0.001). Patients with Edwards Prima showed a trend to a higher regression of left ventricular mass index versus Medtronic Mosaic recipients (p = 0.07).
Conclusions. After aortic valve replacement, stented and stentless bioprostheses exhibited similar results with a more evident hemodynamic improvement during follow-up in the stentless valves. Stented bioprostheses of new generation, however, may parallel the hemodynamic performance of stentless valves and appear to be a valid alternative for aortic valve replacement in elderly patients with a small aortic annulus.


Поделиться:




Комментарии
Смотри также
17 декабря 2001  |  00:12
Durability of aortic valve preservation and root reconstruction in acute type A aortic dissection
Durability of aortic valve preservation and root reconstruction in acute type A aortic dissection
17 декабря 2001  |  00:12
Homograft replacement of mitral valve in children
Homograft replacement of mitral valve in children
17 декабря 2001  |  00:12
Immediate and long-term results of valve replacement for native and prosthetic valve endocarditis
Immediate and long-term results of valve replacement for native and prosthetic valve endocarditis
14 декабря 2001  |  00:12
Особенности инфарктов миокарда, развившихся в дневное и ночное время.
Особенности инфарктов миокарда, развившихся в дневное и ночное время.
14 декабря 2001  |  00:12
Эндокардит. Стертая клиническая картина
Эндокардит. Стертая клиническая картина